Product
Newtons4th
Precision Power Analyzers
Phase Sensitive Multimeters
email: sales@asiainstruments.com
Sales & Application: +65 81127620
Tech Support: support@asiainstruments.com
• 0.04% basic accuracy
• Frequency range dc and 10mHz to 2MHz
• High precision internal shunts
• 1000Vrms - 3000Vpk direct voltage input
• 30Arms – 300Apk direct current input
• 5 millidegree basic phase accuracy
• Six mode of operations
• Frequency response analyzer (FRA)
• Vector voltmeter (VVM)
• Harmonics Analyzer
• Power meter
• RMS voltmeter
• LCR Meter
Power Meter applications
• Power profile testing
• SMPS standby analysis
• Distortion analysis
• PFC testing
LCR Example applications
• Component testing
• Electrochemistry
• Circuit impedance analysis
• Testing resonance
VVM Example applications
• Electrochemical materials analysis
• Current transformer testing
• Phase meter calibration
FRA Example applications
• Power supply gain and phase analysis
• Electronic filter design and test
• Speaker and amplifier test
• Mechanical vibration analysis
• Electro-Mechanical control loop analysis
• Isolated inputs
• dc, 10uHz to 2.4MHz
• RS232, printer port and optional GPIB
• Graphic electroluminescent display
• 10mV to 500V (cat II) ranges
• Automatic frequency sweep
• Alarm on any measurement
• 100 non-volatile program stores
Functions:
• 2 channel wideband true RMS
Voltmeter with direct input up to 500Vpk
• Signal Generator
• Frequency Response Analyser
• Vector Voltmeter
• Pulse Generator
• Selective Level Meter
• Phase Meter
• LCR Analyser
• Transformer Analyser
• Harmonic Analyser
• 2 channel low frequency DSO
• Dual Frequency Generator
• White Noise Generator
• Power Meter
• Phase Sensitive Detector
Example Applications:
• Electrochemical materials analysis, current transformer testing, phase meter calibration
• LCR testing of passive components
• Electronic Filter design and test
• Electrochemistry Impedance Testing
• Audio Sensor, Speaker, Amplifier Testing
• Power analysis
• Gain and Phase testing e.g.
PSU Closed Loop Feedback
Mechanical vibration and resonance
Instrumentation Frequency Response
• Testing electroluminescent lamps
• Transformer testing:
All conventional transformer functions plus telecom transformer tests. Frequency sweep available on all functions.
• Testing high voltage capacitors or piezo electric transducers up to 100kHz at 800V pk-pk
Features:
• Phase accuracy better than 0.1° at 100kHz and better than 1° at 1MHz (same range).
• Tan of angle resolved to 0.0001.
• 100uHz to 2.4MHz frequency range.
• In-phase and quadrature magnitudes, ratio, phase, LVDT measurement.
• Magnitudes, gain, dB and phase. Displays and prints bode plots.
• Parallel and series LCR, phase, tand and Q factor. Displays and prints sweep results.
• True rms, oscilloscope, harmonics & thd.
• 1mV to 10V peak isolated input ranges.
• Data streaming to 1500readings/s.
• Continuously variable generator frequency, or uses test circuit frequency.
• RS232 and printer port; IEEE488 option.
• Graphic electroluminescent display.
• Convenient tower format lifts display and keyboard above leads, or 19” rack format.